intelligent controller
Product Detailed
intelligent controller :
1.Controls for solar water heater.
2.High quality and easy to operate.
Intelligent Controller:
Suitable for separated pressurized solar system
2. Self power consumption: <3W
3. Measuring accuracy of temperature: ±2
4. Temperature range of measurement: 0150
5. Maximum power of controlled circulation pump: possible to
control 2 pumps, every power≤600W
6. Power of auxiliary electrical booster ≤2000W ( standard
collocation),≤3000W not standard,selection available
7. Inputs: 5 inputs, Pt-1000 for collector, sensor temperature
≤500 ( silicon cable ≤280), NTC10K,B=3950 for tank,
sensor temperature ≤135, ( PVC cable ≤105)
8. Outputs: 4 outputs, one for electrical booster, 2 for circulation
pump or 3-way electromagnetic valve)
9. Ambient temperature range: -1050
10.Water protection grade: IP40.
2. available systems ( 1-6 system available )
System1: 1 collector array - 1 storage tank - 1 pump
System2: 1 collector array - 2 storage tanks - 2 pumps
System3: 1 collector array - 1 storage tank - 1 pump and
back-up resource
System4: 1 collector array - 1 storage tank - 2 pumps and
hot water return heating
System5: 1 collector array - 1 storage tank - 2 pumps and
swimming pool system controlling
System6: 1 collector array - 1 storage tank - 1 pump - 1
electromagnetic valve and swimming pool
controlling
3. Speed controlling of circulation pump
4. Temperature difference on/off
5. Maximum tank temperature
6. Maximum collector temperature
7. Collector emergency cut-off
8. Limitation operation of collector at low temperature
9. Frost protection
10. Temperature controlled hot water circulation pump
11. Time controlled hot water circulation pump
12. Temperature controlled auxiliary heating during three time section
13. Holiday function
14. Thermostat of tank
15. Temperature difference adjustment of back-up boiler and heat
exchanger
16. Auto function
17. Auxiliary function/(a.Temperature difference controlling T2,
b.Heating return increasing,c.high temperature by-pass
18. Protection functions ( a. Memory protection, b. anti-bacteria
protection , c. anti- dry heating protection)